EPA 608 at a glance, with the source for every line
Every row below is quoted from a document published by EPA and carries the date we checked it. Where EPA publishes nothing, the row says so instead of quoting a number from somewhere else.
- Who has to be certified
- EPA regulations (40 CFR Part 82, Subpart F) under Section 608 of the Clean Air Act require that technicians who maintain, service, repair, or dispose of equipment that could release refrigerants into the atmosphere must be certified.Source: U.S. Environmental Protection Agency, verified 7 August 2026
- The rule it comes from
- 40 CFR Part 82, Subpart F, under Section 608 of the Clean Air Act.Source: U.S. Environmental Protection Agency, verified 7 August 2026
- The four certification types
- Type I for servicing small appliances · Type II for servicing or disposing of high- or very high-pressure appliances, except small appliances and MVACs · Type III for servicing or disposing of low-pressure appliances · Universal for servicing all types of equipment.Source: U.S. Environmental Protection Agency, verified 7 August 2026
- Required evacuation levels
- Inches of Hg vacuum, relative to 29.9 inches Hg standard atmospheric pressure, for equipment made before / after November 15, 1993. Very high-pressure appliance 0 / 0. High-pressure appliance with a full charge under 200 pounds 0 / 0, at 200 pounds or more 4 / 10. Medium-pressure appliance under 200 pounds 4 / 10, at 200 pounds or more 4 / 15. Low-pressure appliance 25 mm Hg absolute in both.Source: U.S. Environmental Protection Agency, Stationary Refrigeration Service Practice Requirements, verified 7 August 2026EPA labels the two columns Using pre-1993 equipment and Using post-1993 equipment. The requirement covers appliances with more than five pounds of refrigerant, when opening equipment for maintenance, service, repair or disposal. EPA lists separate exceptions to it.
- How long it lasts
- Section 608 Technician Certification credentials do not expire.Source: U.S. Environmental Protection Agency, verified 7 August 2026
- Open book vs proctored
- Core tests taken as an open book exam cannot be used to get your Universal Certification. The core test must be taken as a proctored exam in order to attain Universal Certification.Source: U.S. Environmental Protection Agency, verified 7 August 2026
- What Universal requires
- To receive Universal certification, an individual must pass the examinations at all levels for stationary refrigeration and cooling equipment under closed book, secure, proctored conditions through an EPA approved Section 608 testing and certification organization.Source: U.S. Environmental Protection Agency, verified 7 August 2026
- Apprentices
- Apprentices are exempt from certification requirements provided they are closely and continually supervised by a certified technician.Source: U.S. Environmental Protection Agency, verified 7 August 2026
- How fast you get results
- EPA regulations allow testing organizations up to 30 days from the date of the test to issue test results and certification cards.Source: U.S. Environmental Protection Agency, verified 7 August 2026
- Passing score
- The EPA Universal, Type I, Type II, and Type III exams have a passing score of 70%.Source: North American Technician Excellence (NATE), an EPA-approved Section 608 certifying organization, verified 7 August 2026Checked on 2026-08-07 against NATE, an EPA-approved Section 608 certifying organization. EPA itself does not publish a cut score; NATE publishes 70 percent for the exams it administers. The app’s 70 percent practice threshold is a separate in-app readiness target.
- Who issues the card
- EPA does not issue certification cards. Cards come from the EPA-approved certifying organization that administered your test.Source: U.S. Environmental Protection Agency, verified 7 August 2026
- Exam fee
- Not published by EPA. The EPA does not set or publish an exam fee. Price is set by the EPA-approved certifying organization you test through, so it varies by proctor and by state.Checked against: U.S. Environmental Protection Agency, Section 608 technician certification pages, verified 7 August 2026
- Pass rate
- Not published by EPA. The EPA does not publish a pass rate for Section 608 certification, and pass rates would in any case differ by certifying organization.Checked against: U.S. Environmental Protection Agency, Section 608 technician certification pages, verified 7 August 2026
- Questions per section
- Not published by EPA. The EPA publishes test topic groups for Core and each type but does not publish a question count per section on its certification pages. Widely repeated figures are not sourced to the EPA.Checked against: U.S. Environmental Protection Agency, Test Topics, verified 7 August 2026
- Section weighting
- Not published by EPA. The EPA lists test topics for Core, Type I, Type II and Type III but publishes no percentage weighting, so no official blueprint table is shown on this page.Checked against: U.S. Environmental Protection Agency, Test Topics, verified 7 August 2026
- Time limit
- Not published by EPA. EPA’s Section 608 Technician Certification page states no time limit for the certification exam. Ask the EPA-approved certifying organization that administers yours.Checked against: EPA, Section 608 Technician Certification, verified 7 August 2026
Always verify: certification types, testing rules and fees come from the EPA and the certifying organization you test through, so confirm current details at epa.gov/section608 before you book.
What our EPA 608 question bank covers
| Category | Questions in our bank | Share of our bank |
|---|---|---|
| Core Section Group I fundamentals: environmental impacts, the Clean Air Act and Section 608 rules, refrigeration basics, recovery techniques, evacuation, safety and shipping. | 1,866 | 34.3% |
| Type I · Small appliances Small appliances: factory-manufactured, charged and hermetically sealed units. Recovery requirements, recovery techniques and safety. | 1,164 | 21.4% |
| Type II · High pressure High- and very high-pressure appliances other than small appliances and MVACs. Leak detection, leak repair, recovery, and refrigeration principles. | 1,248 | 22.9% |
| Type III · Low pressure Low-pressure appliances such as centrifugal chillers. Leak detection and repair, recovery, recharging techniques and safety. | 1,167 | 21.4% |
Scroll the table sideways to see every column.